Key Features
-Cuts energy usage and costs with up to 95% efficiency in online double conversion mode and 98% in high efficiency mode
-Provides more real power (watts) to protect more equipment and leave room for expanding IT systems with a 0.9 power factor
-Simplifies UPS monitoring and management with a bright LCD user interface and free intuitive power management software
-Increases battery service life and system uptime with ABM battery-charging technology and hot-swappable batteries
-Maximizes runtimes with optional extended battery modules
Product Features
-Double-conversion design for superior power protection
The 9130 is constantly monitoring power conditions - regulating both voltage and frequency. Even when presented with the most severe power problems, this UPS's output remains within three percent of nominal voltage.
-More real power
High 0.9 output power factor enables the 9130 to provide its full power capability to modern IT equipment that may have a wide range of leading and lagging power factors. With a 0.99 input power factor, this UPS avoids the disturbances that some energy converters tend to cause.
-Advanced design and self monitoring for premium availability
The 9130 continually monitors voltage, temperature, internal element functions, battery health, battery state-of-charge and runtime remaining. If the UPS detects a potential problem with any of these measures, it sends alarms or takes corrective action, with no interruption in power. At the end of an alarm condition, the 9130 automatically reverts from bypass to normal operation.
-Stronger, longer battery life with exclusive ABM technology
Most UPS manufacturers on the market today employ a constant 'trickle-charging' system, which can ultimately reduce potential battery service life by as much as 50 percent. In contrast, ABM technology uses sophisticated sensing circuitry and an innovative three-stage charging technique that significantly extends UPS batteries' useful service life while optimizing their recharge time.
-External battery modules for extended runtime
During a power outage, internal batteries in the 9130 keep loads running long enough to gracefully shut down systems. Add more runtime at any time, with up to four external battery modules to run systems for hours if necessary. These battery modules are hot-swappable and can be replaced at any time without powering down the UPS or protected loads. You can also start up the UPS and power its loads with battery power.
Eaton 9130 1500
The Eaton 9130 UPS delivers online power quality and scalable battery runtimes for servers, voice and data networks, storage systems and other IT equipment. With an efficiency rating of 95% in online double conversion and 98% in high efficiency mode the 9130 UPS cuts energy costs while significantly extending battery service life with ABM technology. The 9130 UPS also has a bright LCD user interface to simplify monitoring.
General | |
Topology | Online, double-conversion |
Configuration | Tower |
Part Number | 103006435-6591 |
Color | Black |
Rating (VA/Watts) | 1500/1350 |
Diagnostics | Full system self-test |
UPS Bypass | Automatic bypass |
Dimensions (H x W x D, mm) | 230 x 160 x 430 |
Weight (kg) | 19 |
Warranty | 3 years on electronics, 2 years on battery |
Efficiency | 94% in high-efficiency mode; 90% in online mode |
Electrical Input | |
Connection | (1) IEC-320-C14 ![]() |
Input Cord | Schoko to IEC C13 (1) |
Input Voltage Range | 180-276 Vac (with load PF of 0.7) |
Nominal Voltage | 220–240V |
Frequency | 50/60 Hz |
Frequency Range | 45–65 Hz |
Nominal Current | 6.5A @230V |
Breaker Ratings | 10A |
Electrical Output | |
Output Receptacles | (6) IEC-320-C13 ![]() |
Power Cables | IEC C13-C14 (2) |
On Utility Voltage Regulation | ±3% of nominal |
On Battery Voltage Regulation | ±3% of nominal |
Power Factor | 0.9 |
Frequency Regulation | ±3% Hz online |
Load Crest Factor | 3 to 1 |
Battery | |
Battery Description | VRLA 12V/9 Ah (internal and External) |
Battery Type | Replaceable maintenance free sealed lead acid |
Battery Replacement | Hot-swappable internal batteries |
Start On Battery | Allows start of UPS without utility input |
Communications | |
User Interface | Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish |
LEDs | Four status-indicating LEDs |
Communication Ports | RS-232 and USB HID port as standard |
Relay Output | Common alarm standard |
Communications Card Slots | Optional SNMP/Web card for monitoring in SNMP-based networks, monitoring through Web browser interface. Relay card for integration to industrial environment and BMS, remote shutdown for IBM AS/400 systems |
Environmental & Standards | |
Heat Dissipation (BTU) | Line: 750, Bat: 1011 |
Audible Noise | <44 dB |
Operating Temperature | 0?C to +40?C |
Performance - Safety - EMC | CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2), GS |
Storage Temperature | -20?C to +40?C with batteries and -25?C to +55?C without batteries |
Relative Humidity | 5–90% non-condensing |
Tags:
WHAT'S INCLUDED | |
---|---|
Warranty | 2 Years |